Prisma Content Decisioning service connects to a ESNI SCTE-224 database to perform placement decisioning based on ESNI SCTE-224 events.

To configure the input, follow these steps:

1. Select the **Input** tab.

2. Configure the following settings.

   <table>
     <thead>
       <tr>
         <th style="text-align: left">Parameter</th>
         <th style="text-align: left">Description</th>
       </tr>
     </thead>
     <tbody>
       <tr>
         <td style="text-align: left">Type</td>
         <td style="text-align: left">Select <strong>ESNI SCTE-224</strong>.</td>
       </tr>
       <tr>
         <td style="text-align: left">Ignore metadata</td>
         <td style="text-align: left">Check this box if ESNI SCTE-224 metadata are not used in decisioning to improve performance.</td>
       </tr>
       <tr>
         <td style="text-align: left">Polling period</td>
         <td style="text-align: left">Define the refresh period when the Content Decision retrieves data from the ESNI SCTE-224 server, usually 60 seconds.</td>
       </tr>
     </tbody>
   </table>

3. In the **ESNI servers** section, select **Add** to configure the ESNI servers that will be used as input.

4. Configure the following settings.

   <table>
     <thead>
       <tr>
         <th style="text-align: left">Parameter</th>
         <th style="text-align: left">Description</th>
       </tr>
     </thead>
     <tbody>
       <tr>
         <td style="text-align: left">Provider</td>
         <td style="text-align: left">Indicate the content provider ID as defined in SCTE-130-3. Each SCTE-224 data base is linked to a provider ID.</td>
       </tr>
       <tr>
         <td style="text-align: left">URL</td>
         <td style="text-align: left">You can either enter the URL of SCTE-224 events database or select a value from the drop-down list of ESNI SCTE-224 data base managed by Prisma via the Viewing Policy Manager services.</td>
       </tr>
     </tbody>
   </table>