## Configuring Remux ECMs

1. Display the services.

2. Click `Edit` icon to edit the services and display the parameters. The transport stream parameters display.

3. Select the service or component.

4. You can either add a Remux ECM if none exists or select an existing Remux ECM to display.

   <blockquote data-callout="note"><strong>Note</strong><p>You can change the order of the Remux ECMs within the service or component by selecting that item and selecting a direction.</p></blockquote>

   ![Move up and Move down in the Remux ECM menu](/images/legacy-multiplexer/move-remux-ecms.webp)

5. Enter a user-friendly **Name**.

6. Select the **Mode**.

   - **Remux By CAS ID**: Enter the incoming **CAS ID** of the ECM to remux.

     ![Remux By CAS ID mode and CAS ID field](/images/legacy-multiplexer/remux-by-cas.webp)

   - **Remux By PID**: Enter the incoming **Input PID** of the ECM to remux.

     ![Remux By PID mode and input PID field](/images/legacy-multiplexer/remux-by-pid.webp)

   - **Remux By Position**: Enter the **CA Descriptor position** of the incoming ECM to remux.\
     Position index is based only on the CA Descriptors and is zero based. Depending on the number of CA Descriptors available, possible position could be 0 or 1 (for 2 CA Descriptors), 0, 1 or 2 (for 3 CA Descriptors), etc.

     ![Remux By Position mode and Position field](/images/legacy-multiplexer/remux-by-position.webp)

7. Enter the **Input Program** number that contains the ECM to remux.

8. Enter the **Output PID** value that will be applied to the outgoing Remuxed ECM.

9. Enter the **Output CAS ID** value of the Remuxed ECM that will be signaled in the CA Descriptor.

10. Select the **Private Data Source** mode:

    - **Extract from input PMT**: Tracks the incoming changes in private data on the incoming ECM.
    - **User specified private data**: Overrides the private data on the remuxed ECM.

11. Select the **ECM reference** in the output PMT mode:

    - **Always include in PMT**: The Remux ECM will always be signaled in the output PMT table.
    - **Follow source**: The output PMT table will only signal the Remux ECM if the incoming PMT contains the ECM that is to be remuxed.
    - **Do not include in PMT**: The Remux ECM is not signaled in the output PMT table.

12. To enable an alarm to be raised when the required incoming ECM is missing:

    1. Check the “Alarm if input component is missing” box.

    2. Specify a **Raise Alarm After** time in milliseconds.

    3. Provide any **User Alarm Text** to be displayed with the alarm.

13. For the Remux ECM to contribute to the input health monitoring, check the “Component Contributes For Input Health Monitoring” box.

    ![Missing-component alarm and input health monitoring controls](/images/legacy-multiplexer/remux-ecm-alarm-settings.webp)

14. Select the incoming source that contains the ECM to be remuxed.
