The Receiver can extract SCTE-35 messages presented in the incoming TS on a data PID, extract the information and insert it into the output SDI as SCTE-104 information.

<blockquote data-callout="note"><strong>Note</strong><p>This functionality is available for each decode service available on <strong>RX1</strong> or <strong>MK.IO Beam.</strong></p></blockquote>

The only commands supported by this functionality are the following:

- `splice_null()` with `splice_command_type 0`.\
  The command is passed silently through the receiver.
- `splice_insert()` with `splice_command_type 5`.\
  The command allows the passthrough of splice network in/out and splice cancel messages.
- `time_signal()` with `splice_command_type 6`

A `time_signal()` command can be extended with an optional `segmentation_descriptor()`. This will be translated into a SCTE-104 `multiple_operation_message` comprising a `time_signal_request_data()` followed by an `insert_segmentation_descriptor_request_data()`.

This is controlled from both the **Input** and **Outputs** tab of the desired receiver service:

1. From the **Home** page, select the **RECEIVER** item from the required feed then click `Edit` icon.

2. From the **Parameters** section, select the **Decoding** tab, then click the **Data** sub-tab.

   - From the **Input** drop-down list select either **Auto** or the PID with the SCTE-35 data.

   - From the **Data type** drop-down list, select **SCTE 35 splicing**.

3. From the **Parameters** section, navigate to the **Output** tab, then select the **Data** tab.

4. From the **SCTE 104 splicing** drop-down list, you can select the line to insert the generated SCTE-104 message within these limits:
   - Line 7- line 41 (field 1)
   - Line 569- line 583 (field 2)

Within the **SCTE 104 splicing** configuration pane, select the **Include time\_signal** checkbox to ensure SCTE-35 `time_signal()` commands are translated into SCTE-104 `time_signal_request_data()` commands. This will also translate any SCTE-35 `segmentation_descriptor()` commands which are attached to the `time_signal()` to SCTE-104 `insert_segmentation_descriptor_request_data()` commands.