Connect the RX1 to its control network before you configure a feed.

## Set the control IP address

Use the RX1 front panel to [set the control IP address](/traditional-products-and-appliances/products/rx1/front-panel#set-the-control-ip-address).

## Connect to the Controller

[Connect to the Controller](/traditional-products-and-appliances/components/controller/connection).

## Configure a basic Receiver service

The following example uses an ASI input and SDI output.

1. From the Home page, click **Add feed**. A new pane is displayed.

2. Select **Receiver** among the feed types and enter a **Feed name**. A new feed will now be available.

3. Edit the new feed: hover the bottom right corner of the pane and click `Edit` icon. The new service is now created and must be edited before starting.

4. Set the input source configuration from the newly visible service edit screen: fill in the required parameters for the input type required. For an ASI input, set **TS packet size** and **Port**.

5. Set the [decoding configuration](/traditional-products-and-appliances/components/receiver/decoding).

   1. Open the **Audio** tab and click **Decode all input audio**.

   2. Open the **Data** tab and click **Decode all input data**.

   3. Select the **Data type** (Ancillary or Teletext) for each component in the data input list.

6. Set the [output configuration](/traditional-products-and-appliances/components/receiver/output#configure-the-output-profile).

   On the **Output** tab, the **SDI 1** settings include **Link mode** and **Output interface**.

   1. If you have [UHD video output](/traditional-products-and-appliances/components/receiver/parameters#general-parameters), then set the output link format to be either quadrant or interleaved.

   2. Open the **Audio** tab and select **Add all**.

   3. Then, for each component in the audio output list, select where to embed it in the SDI output.

   4. Open the **Data** tab then, for each VANC type, from the drop down, select either **OFF** or the line required.

## Verify the feed

Start the configured feed from the **Home** page. Select **Re-order feeds** to show running feeds at the top. Check the thumbnail for the feed you started. See [Manage feeds](/traditional-products-and-appliances/products/rx1/manage-feeds#show-running-feeds-on-top).

## Related topics

[Typical use cases](/traditional-products-and-appliances/products/rx1/use-cases)