Configuring a Live encoding service is a 3-step procedure:
- Step #1: Create a Live encoding service.
- Step #2: Configure the Live Encoding service
- Step #3: Assign a server to run the service.
Step #1: Create a Live encoding service
Select Services > Add service > Live encoding. The service General tab is displayed.
Step #2: Configure the Live Encoding service
To configure Live Encoder, follow these steps:
- Configure service general parameters.
- Configure input parameters.
- Configure encoding parameters.
- Configure output parameters.
Configure service general parameters
-
From the General tab, enter a service name, in our example, st2110-eas.
-
Enter the name of the ESAM network interface, in our example, we are using the management interface, eth0.
-
Select the Activate checkbox to enable the Automation features then configure the parameters:
Parameter Value Description Interface Type ESAM Protocol used with automation system. POIS URL Use the ESAM end point from the Prisma Stream Conditioning service. Live Encoder sends status to this URL. Its path is /api/esam/streamConditionings/<ENDPOINT_ID>. Use the endpoint ID from Connections and the address, protocol, and port for your Prisma Controller.POIS network name st2110-eas ID shared with the POIS for the current channel.
Same as the Network name in Stream Conditioning > Connections.POIS zone identity Zone1 The area ID for this channel distribution. Commonly used for regionalization.
Same as the Zone identity in Stream Conditioning > Connections.Assets directory (Leave empty) You can specify the directory where assets are stored. Must be an absolute directory path (starting by "/"). For logo and blackout files, an http url is also possible.
Configure input parameters
-
Open the Input tab to configure input according to your network configuration.
-
Configure the General parameters: select MediaComposer for input Type.
-
Configure the Live source management parameters:
Parameter Value Description Default service ID st2110-eas ID of the live content that will be used at the start of the service. You can either:
- select an existing ID. If required, this ID can be directly modified via thebutton.
- or create a new ID: either immediately by clicking the + button, or later from the Settings > Live service lineup left-side menu panel.
Note: IDs are defined in the lineup configuration file.Default frame rate 50p Default frame rate used when live input is not yet detected. -
Configure the File source management parameters:
Parameter Value Description Auto Return to Live Select this checkbox. If checked, returns to live at end of the offline source playlist.
Note: Unused in Switch to Live use case.Return to Live on error Select this checkbox. If checked, returns to live if offline source playlist cannot be loaded.
Note: Unused in Switch to Live use case. -
Configure the Sources:
-
Configure the MPEG-2 TS/UDP parameters:
Parameter Value Description Input redundancy Active/Passive Choose the redundancy settings. Two modes can be set when two multicast sources (primary and secondary) are available:
- In Active/Passive mode, the passive source is idle and does not even join the multicast address or capture UDP packets.
- In Active/Active mode, both sources capture in parallel, provide statistics on transport and demux layers, but only one source is fully decoded at any given time.Primary interface eth2 Name of the input interface used to capture the input stream.
Note: In our example, we are using the management interface.Secondary interface (Leave empty) Name of the input interface used to capture the input stream (secondary source).
Note: Only necessary in case of Active/Active redundancy. -
Select the Add SMPTE ST 2110 source button then configure the SMPTE ST 2110 parameters:
Parameter Value Description Input redundancy None Choose the redundancy settings: two modes can be set when two multicast sources (primary and secondary) are available.
In active/passive mode, the passive source is idle and does not even join the multicast address or capture UDP packets.
In active/active mode, both sources capture in parallel, provide statistics on transport and demux layers, but only one source is fully decoded at any given time.NMOS Enabled Leave unchecked. Enables NMOS for EL service. Primary network interface enp175s0f1 Name of the input interface used to capture the input stream.
Note: In our example, we are using the management interface.
-
-
Configure the Input streams selection.
-
Configure the Out of band stream to receive information from Prisma.
Parameter Value Description Type SCTE-35 OOB Select the type of metadata. Network name st2110-eas Corresponds to the Acquisition Point Identity defined in the ESAM specification. Zone identity Zone1 Corresponds to the Zone Identity defined in the ESAM specification. Recover conditioning state if failover Leave to No Selecting POIS enables to keep the conditioning status after an encoder failover by asking to an external system. It requires entering the POIS URL and network interface name. Automation stream Select this checkbox. Activates Live Encoder out-of band interface to communicate with Prisma. You should have the configuration for the out-of-band stream.
-
Select OK. Review the Input tab.
-
Select Save and continue to save your changes.
-
Leave the Media processing parameters unchanged.
Configure encoding parameters
-
From the Encoding tab, create the following streams:
- Video stream,
- Audio stream,
- Metadata stream.
-
Select Save and continue to save your changes.
Configure output parameters
-
Open the Output tab then select Add an output.
-
Configure the General parameters according to your network configuration, especially check that GOP signaling is set to EBP based to be compliant with Live Packaging.
-
Leave the Common MPEG-2 TS parameters unchanged.
-
Configure the Output stream for this service:
-
Scroll to Output streams, then select Add.
-
Configure the output stream:
- IP Address: address to output the stream
- Port: port number to stream on
-
Select the encodings to include in the output stream:
- Video encoding for this output stream
- At least one audio encoding
- Metadata encoding
-
Select OK.
-
-
Select Save and exit to save the configuration and return to Services.
Step #3: Assign a server to run the service
Services require a server to run. Select a server for each service before starting the service.
- Display services.
- Select the field in the Mandatory column to display available servers.
- Enter a server name or select a server from the list.
- Select
to start the service.
- Select
to display service details and to monitor the service.
- Continue to Create alternate content operations.