Skip to content

Configure Stream Conditioning

Set the ESAM connection, network name, zone identity, and endpoints that connect Prisma to Live Encoder.

Updated View as Markdown

To configure your Stream Conditioning service:

  • Select Services > Add service > Stream Conditioning.
  • Enter a service name.

Configure the general parameters

Parameter Value Description
Type ESAM Protocol used to communicate with Live Encoder.
Version 2013 2013 corresponds to specification OC-SP-ESAM-API-I03-131025
Expect notifications Select this checkbox. When enabled, allows Prisma to receive notifications from ESAM devices processing.

Create the end points

  1. From the End points section, select Add. A new window is displayed.

  2. Configure the following settings.

    Parameter Value Description
    ID Auto Set to Auto by default. You can switch to Manual and specify an ID. Encoders or TS processors that will submit received SCTE-35 trigger to Prisma must also configure the ESAM (Prisma) endpoint.
    The general syntax is defined as follows: http://<prisma.controller.ip>:<prisma.controller.port>/api/esam/streamConditionings/<endPointID>
    Network name st2110-eas Identifies the signal acquisition system at a specific site on a specific channel/network feed for all of the contained ResponseSignal. This information will be shared with Live Encoder.
    Note: Must be the same value as the POIS network name in Live Encoder Automation parameters.
    Zone identity Zone1 Allows receiving ESAM status notifications from Live Encoder. Live Encoder uses the ESAM status notification to tell Prisma whether the operations were successfully applied or not.
    Note: Must be the same value as the POIS zone identity in Live Encoder Automation parameters.
    Signal acquisitions http://<ENCODER_CONTROLLER>:<PORT>/api/esam/LiveEncodings/<ENCODER_NETWORK_NAME> Use the encoder controller address and port. Replace <ENCODER_NETWORK_NAME> with the network name configured in Live Encoder. In this workflow the Network name is st2110-eas. The Listening path identifies the acquisition point that returns status notifications. It defaults to /. An example path is /encoder1.
    Attributes Leave empty. EndPoint attributes can be used for additional filtering in SCTE-224 input translations. It allows applying the translation actions to specific endPoint(s).
    Example: name = VIRD, value= NY
  1. Select Ok. The configured end point is added to the list of configured end points.

Verify and save

Select Save and exit to save the configuration and return to Services.

Navigation