This page covers the disk RAID configurations supported for the MK.IO Beam system drive.
Hardware RAID
Hardware RAID has always been supported for the MK.IO Beam system drive. Before 1.14.0 the virtual disk must be created with a 512-byte block size; from 1.14.0 a 4096-byte block size is also supported. Controllers often default to 4096, so check the block size when creating the virtual disk if the server is running an earlier release.
FakeRAID
From MK.IO Beam 1.14.0, FakeRAID is supported for the system drive. The following settings are required:
Setting
Value
Sector size
512 or 4096
OS
RHEL
RAID Type
Linux RAID
RAID Level
RAID 1
Was this page helpful?
Thank you for your feedback.
Your feedback could not be sent. Please try again later.