Skip to content

Metadata

Updated View as Markdown

In-band metadata

Parameter Description
Type

Input metadata expected format.

MPEG-2 TS input type

Parameter Description
PID

Corresponds to the stream identifier in the MPEG2 TS stream. Otherwise use the 'auto' setting for automatic detection.


Possible values:

From 16 to 8190

or "auto"
Delay

If metadata stream is SCTE35, a delay adjusts the trigger time value.


Possible values:

From 30000 to 60.000

ms
Automation stream

Stream used for automation.

SDI or SDI over IP input type

Parameter Description
DPI PID index

Specifies the index to the DPI PID which will carry the resulting splice_info_sections.


Possible values:

From 0 to 65535

Delay

If metadata stream is SCTE35, a delay adjusts the trigger time value.


Possible values:

From 30000 to 60.000

ms

Related information
Configure in-band metadata in input stream

Out-of-band metadata

SCTE-35 OOB

Parameter Description
Network name

Corresponds to the Acquisition Point Identity defined in the ESAM specification.

Zone identity

Corresponds to the Zone Identity defined in the ESAM specification.

ESAM server network interface

Network interface used for ESAM outofband messages applied to the entire service.

Recover conditioning state if failover

If 'POIS' is selected, this options enables to keep the conditioning status after an encoder failover by asking to an external system

.
If POIS is selected, you have to enter the POIS URL and the POIS network interface name.
Note: Configuration of POIS to recover is mandatory if:
- live service is restarted during EAS,
- or input dual source redundancy.
- or live service failover.
Else let the filed to No.
Automation stream

Stream used for automation.

SCTE-104/IP OOB

Parameter Description
DPI PID index

Specifies the index to the DPI PID which will carry the resulting splice_info_sections.


Possible values:

From 0 to 65535

SCTE-104 server network interface

Network interface used for SCTE104 outofband messages applied to the entire service. To modify, open the General tab.


Can be modified from this field if not yet set in the General tab, otherwise the field is grayed out.
Automation stream

Stream used for automation.

Splice countdown insertion

Insert splice countdown field in adaptation field around splice points.

Splice null period

Period between generated splice null commands.


Possible values:

From 400 to 3600000

Related information
Configure out-of-band metadata in input stream
Configure the input

Navigation