Metadata
In-band metadata
Parameter | Description |
---|---|
Type | Input metadata expected format. |
MPEG-2 TS input type
Parameter | Description |
---|---|
PID | Corresponds to the stream identifier in the MPEG2 TS stream. Otherwise use the 'auto' setting for automatic detection. Possible values: From 16 to 8190 or "auto" |
Delay | If metadata stream is SCTE35, a delay adjusts the trigger time value. Possible values: From 30000 to 60.000 ms |
Automation stream | Stream used for automation. |
SDI or SDI over IP input type
Parameter | Description |
---|---|
DPI PID index | Specifies the index to the DPI PID which will carry the resulting splice_info_sections. Possible values: From 0 to 65535 |
Delay | If metadata stream is SCTE35, a delay adjusts the trigger time value. Possible values: From 30000 to 60.000 ms |
Related information
Configure in-band metadata in input stream
Out-of-band metadata
SCTE-35 OOB
Parameter | Description |
---|---|
Network name | Corresponds to the Acquisition Point Identity defined in the ESAM specification. |
Zone identity | Corresponds to the Zone Identity defined in the ESAM specification. |
ESAM server network interface | Network interface used for ESAM outofband messages applied to the entire service. |
Recover conditioning state if failover | If 'POIS' is selected, this options enables to keep the conditioning status after an encoder failover by asking to an external system. If POIS is selected, you have to enter the POIS URL and the POIS network interface name. Note: Configuration of POIS to recover is mandatory if: - live service is restarted during EAS, - or input dual source redundancy. - or live service failover. Else let the filed to No. |
Automation stream | Stream used for automation. |
SCTE-104/IP OOB
Parameter | Description |
---|---|
DPI PID index | Specifies the index to the DPI PID which will carry the resulting splice_info_sections. Possible values: From 0 to 65535 |
SCTE-104 server network interface | Network interface used for SCTE104 outofband messages applied to the entire service. To modify, open the General tab. Can be modified from this field if not yet set in the General tab, otherwise the field is grayed out. |
Automation stream | Stream used for automation. |
Splice countdown insertion | Insert splice countdown field in adaptation field around splice points. |
Splice null period | Period between generated splice null commands. Possible values: From 400 to 3600000 |
Related information
Configure out-of-band metadata in input stream
Configure the input